Operating Principle
Following Faraday’s law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field. In the electromagnetic measuring principle, the following medium is the moving conductor. The voltage induced is proportional to the flow velocity and is supplied to the amplifier by means of two measuring electrodes. The flow volume is calculated by means of the pipe cross section area.
Giá Liên hệ
Mô Tả Chi Tiết
- MÔ TẢ CHI TIẾT
Application






Technical Data
| Certification | ISO9001:2008;CE |
| Diameter | PTFE: DN6-DN600 |
| Hard rubber: DN50-DN2200 | |
| Flow Direction | Positive; Negative |
| Repeatability Error | ±0.1% |
| Accuracy | ±0.5% of rate & ±1.0% of rate |
| Medium Temperature | Hard rubber liner:-20…+60°C |
| High-temp rubber liner: -20…+90°C | |
| PTFE liner: -20…+120 °C | |
| High-temp PTFE liner: -20…+160°C | |
| PFA: -20…+180°C liner: -20…+160°C | |
| Nominal Working Pressure | DN10~DN25≤4.0MPa |
| DN32~DN150≤1.6MPa | |
| DN200~DN600≤1.0MPa | |
| DN700~DN22000≤0.6MPa | |
| Velocity | 0.3-10m/s |
| Ambient Temperature | -20…+60°C |
| Relative Humidity | 5%~95% |
| Comsumed Power | <20W |
——————————————
MỘT SỐ HÌNH ẢNH CỦA DN40